Wire Belden 88760-002-1000 18/2 Shielded Plenum Cable 18AWG/2C 1,000' (Medinah) $592
Wire Belden 88760-002-1000 18/2 Shielded Plenum Cable 18AWG/2C 1,000'
For use in indoor plenum environments but also suitable for outdoor and underground applications.
Prices: $1.07/ft min 50 ft., $0.87/ft 100 ft or more, $0.77/ft 250 ft or more, $0.67/ft 500 ft or more, $592 for the 1,000 ft spool.
Manufacturer: Belden
Model: 88760 002-1000
Description: Plenum Shielded Cable
Condition: New
Packaging Condition Details: No Packaging
Description:
18 AWG stranded (19x30) TC conductors, plenum, FEP insulation, twisted pair, overall Beldfoil® shield (100% coverage), 20 AWG stranded TC drain wire, FEP jacket.
Physical Characteristics (Overall)
Conductor
# Pairs: 1
AWG: 18
Stranding: 19x30 TC
Conductor Material: Tinned Copper
Insulation
Insulation Material: FEP - Fluorinated Ethylene Propylene
Insulation Material Wall Thickness (in.): .007
Outer Shield
Outer Shield Material:
Outer Shield Trade Name Type Outer Shield Material Coverage (%)
Beldfoil® (with shorting fold) Tape Aluminum Foil-Polyester Tape 100.000
Outer Shield Drain Wire AWG:
AWG: 20
Stranding: Stranded
Drain Wire Conductor Material: TC - Tinned Copper
Outer Jacket:
Outer Jacket Material: FEP - Fluorinated Ethylene Propylene
Outer Jacket Material Nom. Wall Thickness (in.): 0.014
Overall Cabling:
Overall Nominal Diameter: 0.146 in.
Pair:
Pair Color Code Chart:
Number Color: 1 Black & Red
Pair Lay Length & Direction:
Lay Length (in.): 2.000
Twists/ft. (twist/ft): 6.000
Mechanical Characteristics (Overall):
Operating Temperature Range: -70°C To +200°C
Bulk Cable Weight: 22 lbs/1000 ft.
Max. Recommended Pulling Tension: 64 lbs.
Min. Bend Radius (Install)/Minor Axis: 1.500 in.
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs:
NEC/(UL) Specification: CMP
CEC/C(UL) Specification: CMP
EU CE Mark: Yes
EU Directive 2000/53/EC (ELV): Yes
EU Directive 2002/95/EC (RoHS): Yes
EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005
EU Directive 2002/96/EC (WEEE): Yes
EU Directive 2003/11/EC (BFR): Yes
CA Prop 65 (CJ for Wire & Cable): Yes
MII Order #39 (China RoHS): Yes
Flame Test
UL Flame Test: NFPA 262
C(UL) Flame Test: FT6
Suitability
Suitability - Indoor: Yes
Suitability - Outdoor: Yes
Suitability - Burial: Yes
Oil Resistance: Yes
Plenum/Non-Plenum
Plenum (Y/N): Yes
Non-Plenum Number: 8760
Electrical Characteristics (Overall)
Nom. Characteristic Impedance: Impedance (Ohm): 29
Nom. Inductance: Inductance (μH/ft): .15
Nom. Capacitance Conductor to Conductor: Capacitance (pF/ft): 51
Nom. Capacitance Cond. to Other Conductor & Shield: Capacitance (pF/ft): 97
Nominal Velocity of Propagation: VP (%): 69
Nominal Delay: Delay (ns/ft): 1.47
Nom. Conductor DC Resistance: DCR @ 20°C (Ohm/1000 ft): 5.5
Nominal Outer Shield DC Resistance: DCR @ 20°C (Ohm/1000 ft): 7.3
Max. Operating Voltage - UL: 300 V RMS
Max. Recommended Current: 5.4 Amps per conductor @ 25°C
Item #: 88760 0021000
Putup Ship: 1,000 FT Spool
Weight: 24.000 Lbs
Color: 002, RED
Item Description: 2#18 FEP SH FEP
Delivery/Shipping available at additional cost to Buyer, dlb PayPal Accepted.
$592
WARNING! Always deal locally with people on SpreadMyAd, when buying OR selling something. You'll eliminate most of your risk for getting scammed by dealing in person. Question deals that involve money transfers, wire transfers, shipping, escrow, promisory notes etc.
Browse Materials in Illinois
Bloomington Normal | Champaign Urbana | Chicago | Decatur | La Salle Co | Mattoon Charleston | Peoria | Rockford | Southern Illinois | Springfield | Western Il